Lincoln Corsair: Body Closures / General Procedures - Power Liftgate Initialization
Programming
NOTE:
This procedure clears and then sets new open and close end points in the RGTM memory.
-
Turn the ignition ON.
-
Using a scan tool perform the RGTM self test to complete power liftgate
initialization. From the diagnostic scan tool, enter TOOLBOX > Self
Test > RGTM > Run Selected Procedure.
Special Tool(s) /
General Equipment
Interior Trim Remover
Inspection
Inspect the body-to-liftgate door dimensions.
Open the liftgate...
Inspection
NOTE:
Removal steps in this procedure may contain installation details.
NOTE:
LH shown, RH similar.
Inspect the body-to-rear door dimensions...
Other information:
Special Tool(s) /
General Equipment
Hose Clamp Remover/Installer
Removal
NOTICE:
During engine repair procedures, cleanliness is extremely
important. All parts must be thoroughly cleaned and any foreign
material, including any material created while cleaning gasket surfaces,
that enters the oil passages, coolant passages or the oil pan, can
cause engine failure...
Materials
Name
Specification
Motorcraft® Silicone Brake Caliper Grease and Dielectric CompoundXG-3-A
ESA-M1C200-AESE-M1C171-A
Removal
NOTE:
Removal steps in this procedure may contain installation details.
Drain the cooling system...